Temperature LCD AC/DC Multimeter Volt Amp Ohm Tester EM5510
Note :
This package doesnot include batteries.
Due to new rules of China Post Air, parcels must not include batteries,
otherwise it will not get through the custom.![]()
> This multimeter is 4000 count, 3 3/4-digit multimeter.
> It can be used to measure DC and AC voltage, DC and AC current,
resistance, capacitance, frequency, diode, temperature, continuity,
duty cycle and electromagnetic field radiation.
> It can be used as a test tool for environment and devices.
> It is a high-performance and versatile meter.![]()






Safety Information >>>
This meter has been designed according to IEC-61010 concerning electronic measuring
instruments with a measurement category (CAT II 600V) and pollution degree 2.
GENERAL SPECIFICATION >>>
> Dimensions (W×L×T): 83×162×47 mm
DC Voltage >>>
| Range | Resolution | Accuracy |
| 400mV | 0.1mV | ±(1.0%+5) |
| 4V | 1mV |
|
| 40V | 10mV | |
| 400V | 100mV | |
| 600V | 1V | ±(1.0%+5) |
| Range | Resolution | Accuracy |
| 4V | 1mV | ±(1.0%+5) |
| 40V | 10mV | |
| 400V | 100mV | |
| 600V | 1V | ±(1.2%+5) |
DC Current >>>
| Range | Resolution | Accuracy |
| 400uA | 0.1uA |
|
| 4000 uA | 1 uA | |
| 40mA | 10 uA | |
| 400mA | 100 uA | |
| 4A | 1mA | ±(1.8%+3) |
| 10A | 10mA | ±(2.0%+5) |
AC Current >>>
| Range | Resolution | Accuracy |
| 400uA | 0.1uA |
±(1.5%+5)
|
| 4000 uA | 1 uA | |
| 40mA | 10 uA | |
| 400mA | 100 uA | |
| 4A | 1mA | ±(2.0%+5) |
| 10A | 10mA | ±(2.5%+5) |
RESISTANCE >>>
| Range | Resolution | Accuracy |
| 400Ω | 0.1Ω | ±(1.0%+5) |
| 4kΩ | 1Ω |
|
| 40 kΩ | 10Ω | |
| 400 kΩ | 100Ω | |
| 4MΩ | 1kΩ | |
| 40MΩ | 10kΩ | ±(2.0%+5) |
FREQUENCY >>>
| Range | Resolution | Accuracy |
| 10Hz | 0.01Hz | ±(1.0%+3) |
| 100Hz | 0.1Hz | ±(0.8%+3) |
| 1kHz | 1 Hz | |
| 10kHz | 10 Hz | |
| 100kHz | 100 Hz | ±(1.0%+3) |
| 200kHz | 1kHz | |
| >200kHz | | Not specified |
CAPACITANCE(use Relative mode) >>>
| Range | Resolution | Accuracy |
| 4nF | 0.001nF | ±(4.0%+5) |
| 40nF | 0.01nF | |
| 400nF | 0.1nF | |
| 4uF | 1nF | |
| 40uF | 10nF | |
| 100uF | 100nF | ±(8.0%+5) |
TEMPERATURE >>>
| Range | Resolution | Accuracy |
| -20℃~400℃ | 0.01℃ | ±1.5%±3℃ |
| 400℃~1000℃ | 1℃ | ±2.0%±3℃ |
DUTY CYCLE >>>
| Range | Resolution | Accuracy |
| 1%~99% | 0.1% | 1Hz~10kHz:±(2.0%+5) |
| >10kHz: not specified |
HUMIDITY(%RH) >>>
| Range | Resolution | Accuracy |
| 30%~90% | 0.1% | --------------------- |
SOUND LEVEL(dB) >>>
| Range | Resolution | Accuracy |
| 35~100dB | 0.1dB | --------------------------------- |
INTENSITY OF ILLUMINATION(Lux) >>>
| Range | Resolution | Accuracy |
| 400x10 Lux | 1 Lux | --------------------------------- |
| 4000x10 Lux | 10Lux |
ACCESSORIES >>>
Test Lead; Temperature probe; Battery; Users Manual; Holster