- Home
- 
			Categories
			- Car Diagnostic Tools
- Original Brand Tools
- Car Key Programmers
- OBD2 Code Scanners
- Truck Heavy Duty Scanners
- ECU Chip Tuning Tools
- Odometer Correction Tools
- VAG Diagnostic Tool
- Original Launch X431 Tools
- Original Autel Tool
- Original Xhorse Tool
- Key Cutting & Locksmith Tools
- Airbag/Service Reset Tools
- OBD2 Cables and Connectors
- AUGOCOM Camshaft Engine Timing Tool
- Other OBDII Vehicle Tools
- Car Key Blanks
- Car Key Chips
- Car Diagnostic Software
- Automotive Electrical Testers & Test Leads
- Auto HID Xenon Light and LED Light
- Automotive Electronics
- Repair & Maintenance Tools
- MB Star Diagnostic Tools
- Health Care
- Special Deals
- Consumer Electronics
- Home & Garden
- Outdoor
- Expired Tools
 
- Top Selling
- New Arrivals
- for MB
- for Porsche
- Xhorse
- for TOYOTA
- for FORD
- Order Tracking
- Drop-ship

3 in 1 PH EC TEMP 0.01 Meter Waterproof Digital EC pen with Automatic temperature compensation for aquarium
- Shipping:
- Airmail Post
 Estimated delivery time: 7-45 working days.See details»
- Returns:
- Return for refund within 7 days,buyer pays return shipping.Read details »
- Support:
-   Online Chat Online Chat WhatsApp WhatsApp Skype Skype Ask a question Ask a question
- Product Details
- Product's Reviews
- Write a Review
- Related Products
Digital Waterproof 0.01 3 in 1 PH EC Meter LCD with backlight temperature with Automatic temperature compensation for aquarium
Specifications:
PH:
Range:0.00~14.00 pH Resolution:0.01 pH Accuracy:±0.1 pH
TDS:
Range:0~19990uS/cm Resolution:10uS/cm Accuracy:士2%F.S
Temperature:
Range:0~50℃(32~122F) Resolution:10uS/cm Accuracy:士2%F.S
Automatic Temperature:
Compensation:0~50℃ Battery Type:4×1.5V(AG13)(NOT INCLUDE) Environment:0~50℃
Dimensions:
188mm×35mm×35mm
Weight:98g
Operating Instructions:
- Turn on the meter.
-     Immerse the electrode in the 
-     solution to be tested. 
-     Stir gently and wait for the reading to stabilize. 
-     Press the ""C/"F"key,choice the C/"F for measuring. 
-     Press the"EC/pH"button,choice the PH or EC for measuring. 
-     After use,turn off the meter. 
-     Rinse the electrode with distilled water to minimize contamination. 
-     Always replace the protective cap after use. 
Note:
EC meter value is the reading×10.
Example:the reading display to 128,actual EC meter value for:128×10=1280us/cm
Calibration:
1)PH
- Rinse the ph electrode first with distilled water,and suck it with filter paper(not included).
-     Turn on the meter.Press the"EC/pH"button,choice the PHfor measuring. 
-     lmmerse the ph electrode in pH 6.86(0r pH7.00)buffer solution:gently shake the meter and wait 
-     for a stable display. 
-     Regulate the trimmer with the Screwdriver provided until display shows"6.86"("7.00)at buffer solution temperature of25℃. 
-     Rinse the ph electrode with distiled water,and suck it with filter paper(not included) 
-     lmmerse the pH electrode in DH4.01 or pH9.18(pH10.0) buffer solution,gently shake the electrode and waiting for the reading to stabilize.The showing value and buffer solution's ph value is within 
-     error range. 
-     The calibration of the instrument's pH range is now complete. 
Important:
-     The ph meter should be recalibrated under following situations: 
-     The meter has been used for long time since the last calibration or use. 
-     The meter has been used in particularly continual conditions. 
-     The utmost accuracy is required. 
2)EC
-     Turn on the meter.Press the "EC/pH"button,choice the EC for measuring. 
-     Immerse the electrode in the distilled water.Activate it about five minutes. 
-     Immerse the electroder in 1413uS/cm calibration solution.And stir it gently. 
-     Unscrew the battery compartment cap on the top of the meter. 
-     Allow the reading to stabilize and with a small screwdriver turn the calibration trimmer until the display shows"141(141×10=1410) 
-     Rinse the electrode with distilled water and suck it with filter paper. 
-     Immerse the electroder in 150uS/cm calibration solution.gently shake it and wait for a stable display.The showing value and buffer solution's value is within error range. 
-     Rinse the electrode with distilled water and suck it with filter paper. 
-     The calibration of the instrument's EC range is now complete. 






 
              
              
              
              
              
              
          
- Related Items
- Recommond Tools
- Hot Sale
- On Sale
- New Arrivals
- Freeshipping Items
- 
		
		
		US$999.00 / piece
- 
		
		
		US$169.00 / piece
- 
		
		
		US$159.00 / piece
- 
		
		
		US$639.00 / piece
- 
		
		
		US$550.05 / piece
- 
		
		
		US$299.00 / piece
- 
		
		
		US$349.00 / piece
- 
		
		
		US$174.99 / piece
- 
		
		
		US$13.99 / piece
- 
		
		
		US$499.00 / piece
- 
		
		
		US$199.00 / piece
- 
		
		
		US$39.99 / piece
- 
		
		
		US$159.00 / piece
- 
		
		
		US$35.99 / piece
- 
		
		
		US$6.90 / piece
- 
		
		
		US$99.99 / piece
- 
		
		
		US$69.99 / piece
- 
		
		
		US$449.00 / piece
- 
		
		
		US$69.99 / piece
- 
		
		
		US$69.99 / piece
- 
		
		
		US$49.00 / piece
- 
		
		
		US$174.99 / piece
- 
		
		
		US$512.45 / piece
- 
		
		
		US$289.00 / piece
- 
		
		
		US$139.00 / piece
- 
		
		
		US$44.99 / piece
- 
		
		
		US$39.00 / piece
- 
		
		
		US$689.00 / piece
- 
		
		
		US$39.18 / piece
- 
		
		
		US$989.00 / piece
- 
		
		
		US$89.99 / piece
- 
		
		
		US$4.99 / piece
- 
		
		
		US$95.00 / piece
- 
		
		
		US$79.00 / piece
- 
		
		
		US$59.00 / piece
- 
		
		
		US$16.00 / piece
Trending Products
- US$129.00 / piece
- US$1,500.00 / piece
- US$59.99 / piece
- US$64.99 / piece
- US$259.00 / piece
- US$1,499.00 / piece
 USD
 USD Euro
  Euro British Pound
  British Pound Australian Dollar
  Australian Dollar






 
 

 
 